Each Cooling towers is manufactured to cool liters per second of water from 0 ______ C (HW) enter ing water 0 temperature to ______ C (CW) leaving 0 water temperature at ______ C (WB) entering wet bulb temperature. The Cooling towers are guaranteed to perform in accordance with the conditions specified without any modifucations.
Water is a precious resource & need to be conserved by one and all. Industries need water to remove the heat from their equipments and machinery. Cooling towers are used to remove this heat from the processed water & by doing so ensures (99%) of water consumption & sewer costs are conserved.
The Cooling towers structure shall be constructed from HDG Steel. All HDG (Hot Dipped Galvanized) are carried out in accordance to ISO 1461 : 1999. The Cooling towers casing shall be constructed from FRP (Fibreglass Reinforced Polyester).
The basin sump shall be constructed from HDG Steel. The basin shall be made of FRP and equipped with drain outlet for ease of cleaning.
Air inlet louvers shall be made from FRP Designed to prevent water splash - out and to minimise sunlight from entering the Cooling towers interior. Louvers are designed to be easily removable intended for easy access to cleaning.
Infill shall be of ultra -voilet ray treated PVC (Polyvinyl Chloride). The PVC infill shall be vacuum-formed with patented intricate design to facilitate a good spread of water over the surface area of crossflow induced draft of air. It also incorporate a built-in drift eliminator.
The hot water distribution shall be of open gravity type basin. It shall be constructed of HDG Steel designed with multiple array of turret-puched holes to facilitate even distribution of stable water sprinkling effect.
Fans shall be axial flow type with FRP blades. The fans shall be designed to provide necessary air flow for heat transfer. Fan blades shall be assembled. Balanced and pitched. The fan shall
Fans shall be axial flow type with FRP blades. The fans shall be designed to provide necessary air flow for heat transfer. Fan blades shall be assembled. Balanced and pitched. The fan shall operate within a FRP fan cylinder, which provides a streamlined air entry and minimum tip clearance for maximum fan efficiency.
All bolts & nuts shall be 304 stainless steel.
The fan motor(s) shall be to IP55 standard with Class insulation, specifically designed for Cooling towers service. The motor shall be located adjacent to the fan cylinder for ease of maintenance and increased motor life expectancy. The motor shall be fully outside of the moist discharge air stream.
the mechanical support shall be of HDG Steel and bolted to the top pf fan cylinder. HDG Steel fan guard shall be bolted to the top of mechanical support for safety measure. Extended lubrication lines shall be provided to the bearings with grease nipples located outside for ease of schedule maintenance.